0110 and approved by UL and CSA. Page 2: Ordering Information OFF- or ON-time settings are possible. 05 s to 30 h 5v relay datasheet pdf from 1. 2 s to 300 h depending on the model to be used.

Models with a flicker ON start or flicker OFF start are available. 2 to 12 3 to 30 30 to 300 3 to 30 Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. Characteristics Accuracy of operating time 0. OFF according to the time set by the ON- and OFF-time setting knob. Page 6 Flicker OFF start 0. Power indicator Not lit indicator Not lit Output Output ON set time : OFF set time Flicker ON start 0.

Page 7 H3CR-F H3CR-F Dimensions Note: All units are in millimeters unless otherwise indicated. Page 8 200 to 240 VAC Time-limit contact and instantaneous contact 100 to 120 VAC H3CR-G8EL 200 to 240 VAC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-G8L 100 to 120 VAC Supply voltage Model Number Legend: H3CR – 1. Page 11 5,000 1,000 Reference: A maximum current of 0. 7 ms and a maximum current of 0.

In both cases, a life of 100,000 operations can be expected. O Functions Inputs Outputs Control output If the time reaches the value set with the time setting knob, the star operation output will be turned OFF and there will be delta operation output after the set star-delta transfer time has elapsed. Time Setting Ring C onto the time setting knob so that the stopper of Time Setting Ring C is on the right edge of the reset lock position of the Panel cover. Note: Leave terminals 1, 3, and 4 open.

Do not use Do not use them as relay terminals. 5 to 6 1 to 12 Min. Note: If the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time. Page 19 5,000 1,000 Reference: A maximum current of 0. O Functions Inputs Reset Turns off the control output and resets the elapsed time.

Outputs Control output Operates instantaneously when the power is turned on and time-limit resets when the set time is up after the power is turned off. Page 22 H3CR-H H3CR-H Dimensions Note: All units are in millimeters unless otherwise indicated. Power supply Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. No time unit selector is available. Page 28 Y92A-48B Y92A-48B The protective cover protects the front panel, particularly the time setting section, against dust, dirt, and water. It also prevents the set value from being altered due to accidental contact with the time set- ting knob.

The Y92A-48B Protective Cover is made of a hard plas- tic and therefore it must be removed to change the timer set value. Input An interval of 3 s minimum is required to turn on the H3CR after the Power supply terminal H3CR is turned off. If the H3CR is turned on and off repeatedly with an interval of shorter than 3 s, the internal parts of the H3CR may deteriorate and the H3CR may malfunction. The above figures are all approximations and should be used for reference only. The inrush current is given mainly for DC models for the required power supply design specifications. H ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0. To convert grams into ounces, multiply by 0. L86-E1-2B In the interest of product improvement, specifications are subject to change without notice. By pressing ‘print’ button you will print only current page. To print the manual completely, please, download it. Don’t show me this message again.

Advanced tuning which includes fuzzy self-tuning. Conforms to international EMC and safety standards. Note: A single Output Unit and Option Unit can be mounted to each Base Unit. The Digital Controller can be provided together with an inspection report. Refer to the following legend with the suffix “K” when ordering a model provided together with an inspection report. Inspection Report The Digital Controller can be provided together with an inspection report.

Page 3 Note: The indication accuracy of the K1, T, and N thermocouples at a temperature of 100 C or less is 2 C 1 digit maximum. The indication accuracy of the U, L1, and L2 thermocouples at any temperature is 2 C 1 digit maximum. Option Unit Ratings and Characteristics Event inputs Contact input: ON: 1 k max. No-contact input: ON: residual voltage 1. Page 5 Panel Cutouts 65 min.

Recommended panel thickness is 1 to 5 mm. 6 ing space between each Unit. Units must not be closely mounted vertically or horizontally. Fit the two protrusions of the Output Unit into these two holes.